The corona generator is dead — alarm showing, or no output at all — and the line is waiting. Most suppliers won't publish fault-finding guidance for these units (it makes the machine sound fragile), so maintenance teams are left guessing. Here is the systematic version most service engineers actually follow.
Dealing with this station right now?
Send your substrate, target dyne, and station parameters (electrode type, width, line speed) — we answer with specifics for your setup.
Send Your Station DataSafety first, always
These are high-voltage, energy-storing devices. Lock out, tag out, and wait before touching anything HV. Stored charge in transformers, cables, and capacitors does not vanish when the breaker opens. Never bypass interlocks "temporarily." If you have no HV experience, your territory ends at Level 1 below — and that's fine; a large share of "dead generator" calls never get past Level 1.
Level 1 — Supply and peripherals (anyone)
- Input power: breaker tripped? Contactor pulling in? Input voltage present and in range?
- Interlock chain: emergency stop reset? Roll-rotation interlock satisfied? Door switches closed? A surprising share of "no output" events are simply an unsatisfied interlock.
- Panel indication: run/fault lamps and meters — read them against the manual's fault table before opening anything.
Level 2 — Control circuits (electrical maintenance)
- Control transformer output and fuses.
- Start/stop signal chain: external enable, sequence inputs, rotation feedback actually arriving.
- Output adjustment loop: setpoint potentiometer/signal behaving sanely.
Level 3 — High-voltage section (qualified personnel or return to supplier)
- HV transformer and power devices (MOSFET/IGBT stages or oscillator tube, depending on design).
- HV cables and connectors — the classic failure point: insulation embrittlement, moisture ingress, tracking at connectors. Visual inspection for blackening/cracks; insulation resistance test when discharged and safe.
- Matching to the station: if the generator or station was recently replaced or re-paired, suspect mismatch (electrode capacitance vs. output circuit) before condemning the supply — see our matching article.
Repair on site or send it back?
| Situation | Recommended action | |---|---| | Level 1–2 findings | Fix on site; stock fuses/contactors as spares | | HV cable/connector aging | Replace cable (keep a spare on the shelf) | | Transformer / power module failure | Return to manufacturer or a qualified HV shop — do not improvise |
Two preparations that cut downtime
- Spares shelf: fuses, contactors, HV cable set — the "waiting for parts" items.
- Fault log: every event with symptom, lamp states, and action taken. After three or four events you have a failure profile of your unit that no manual can give you.
Generator down, or failing repeatedly?
Send the nameplate, the fault symptoms, and your station parameters — we'll tell you whether this is a Level 1–2 fix, a cable, or a replacement situation, including compatible-replacement options for discontinued units.
Send Your Requirements