Corona Treater Arcing: 5 Causes and How to Fix Them in Order

From the engineering practice behind our Corona Treatment Power Systems.

Who this is forMaintenanceProcess engineer

On this page

Want an engineer's read on this?

Send your parameters or symptoms — an engineer replies with a concrete assessment.

Ask an Engineer

Arcing is the most frequent failure mode on a corona treater — a sharp "crack," a bright concentrated spark instead of an even purple glow, and a stripe of untreated (or punctured) film coming off the roll. The instinctive response — turning the power down — hides the symptom but leaves the film under-treated. Arcing is not solved with the power knob; it is solved by finding out why the discharge is taking a shortcut.

Dealing with this station right now?

Send your substrate, target dyne, and station parameters (electrode type, width, line speed) — we answer with specifics for your setup.

Send Your Station Data

Normal corona vs. arcing

Healthy corona is a uniform, faint violet glow spread across the electrode. Arcing is a concentrated discharge: current funnels through one point. That happens when something on the discharge path creates a weak spot. There are five usual suspects — check them in this order.

1. Contaminated electrode or roll (most likely)

Slip additives, oxidation residue, and dust build up on the electrode face and the covering of the backup roll. Deposits concentrate the discharge. Look for: brownish film, shiny burned spots. Fix: scheduled cleaning — see the maintenance routine below. This cause alone explains a majority of recurring arcing.

2. Uneven air gap

The gap between electrode and roll must be uniform. A deformed electrode, loose mounting, or worn roll covering creates a narrow spot that fires first. Check: measure the gap at several points with feeler gauges against the manufacturer's tolerance.

3. Damaged roll covering

A punctured or worn silicone/ceramic covering develops a permanent conductive path. Signature: arcing always in the same spot, unaffected by cleaning. That's a covering replacement, not a cleaning job.

4. Humidity

High ambient humidity lowers the breakdown threshold of air. If arcing "follows the weather" (rainy season, morning condensation), address workshop dehumidification before touching anything else.

5. Power supply side

Deteriorated HV cable insulation, damp connectors, or generator faults also cause concentrated discharge. Check this last — and mind high-voltage safety: power off, lock out, and wait for discharge before touching HV components.

Three don'ts

  • Don't run long-term at reduced power to "avoid" arcing — under-treated film costs more than the downtime.
  • Don't approach the station live to "see where it sparks."
  • Don't keep running with a fixed-position arc — you are burning the covering and the electrode with every shift.

Prevention

Put two items into the weekly checklist: electrode/roll cleaning (with condition notes) and air-gap measurement. Most arcing announces itself days in advance to anyone keeping those records.

Arcing you can't pin down?

Send us the arc position (fixed or random), the films involved, and when it happens — our engineers will help you localize the cause, on the test bench if you can visit.

Send Your Requirements